Wall Canopy Hoods
Exhaust Only Hoods
The GA2 Series is a Type I, Wall Canopy Hood for use over 450°F, 600°F and 700°F cooking surface temperatures. The aerodynamic design includes a mechanical baffle and performance enhancing lip for exceptional capture and containment.
Product Description
- Exhaust Flow Rates: Superior exhaust flow rates. A 4′ Hood can operate at 150 CFM/ft or 600 total CFM. Available in single or back-to-back configurations.
- ETL Listed: ETL Listed for use over 450°F, 600°F and 700°F cooking surface temperatures, which provides flexibility in designing kitchen ventilation systems. ETL Listed to US and Canadian safety standards, ETL Sanitation Listed and built in accordance with NFPA 96.
- Capture and Containment: Insulated, double-wall rigid front has aerodynamic design that reduces radiant heat into kitchen, prevents condensation and provides exceptional capture and containment of cooking vapors. This is accomplished with the signature ND-2 “mechanical baffle” on the front of the hood’s capture area and the “C-shaped” design of the hood’s capture area. Mechanical baffle provides a built-in wiring chase for optimal positioning of electrical controls and outlets on the front face of the hood without penetrating capture area or requiring external chase way.
- Convenient Design: Factory pre-wired lighting to illuminate the cooking surface is accessible from the bottom of the hood. Fitted with UL Listed, pre-wired, incandescent light fixtures and tempered glass globes to hold up to a standard 100 watt bulb. Pre-punched hanging angles on each end of hood and additional set provided for hoods longer than 12′.
- Construction: Polished stainless steel on the interior and exterior of the front enhance aesthetics. Fully welded and polished front corners. Fabricated from Type 430 stainless steel with option of Type 304 available.
- Channels: Hood comes standard with structural channels on top and wrapper channels on the bottom.
- Reduced Weight: Rigid single wall end panels reduce weight.
Performance
AVG. COOKING SURFACE TEMP. (°F) | CONFIGURATION | MIN. EXHAUST CFM / FT. |
---|---|---|
450°F | Single Wall Hood 2 Wall Hoods Back-to-Back | 150 300 |
600°F | Single Wall Hood 2 Wall Hoods Back-to-Back | 200 400 |
700°F | Single Wall Hood 2 Wall Hoods Back-to-Back | 250 500 |
Recommended Duct Sizing: Exhaust – Based on 1500 FPM
- Grease Extraction: All hoods come standard with stainless steel baffle filters and a deep grease trough which allows for easy cleaning. Captrate Combo® and Captrate Solo® filters are optional. Grease drain system with removable 1/2 pint cup for easy cleaning. Standard filter stops eliminate gaps between filters.
- Reduced Lead Times and Shipping Costs: Produced on a high volume assembly line at one of six manufacturing facilities to reduce lead times and shipping costs.
- Clearance to Combustibles: Standard built in 3″ rear standoff to meet NFPA 96 requirements, when installed in a wall application.
Controls: Hoods can be equipped with modular utility cabinets and end standoffs. Optional listed light and fan control switches flush mounted and pre-wired through electrical chase way. - Optional Make-Up Air: Make-up air can be supplied through optional front and/or side plenums (GA2 Series with PSP or AC-PSP Accessory).
- Optional Self Cleaning Technology: The Self Cleaning Hood option adds a spray bar that extends the full length of the hood immediately behind the filters. The system cleans grease from the plenum and portion of the duct with the daily hot water spray cycle.
- Optional CORE Protection: The CORE Fire Protection System is an automatic, pre-engineered fire suppression system which is ETL listed to UL Standard 300. The CORE Protection System is designed to provide primary coverage for ventilating equipment including hoods, ducts, plenum and filters.
- Optional Heat Recovery Coil: This option is available for hoods with CORE Protection. A listed coil accessory can be added to the hood plenum to recover heat from the exhaust stream. Warm air in the exhaust stream passes over the coil and heats the cold water in the coil, acting as a preheater on the hot water supply line for the restaurant or facility.
Features
Low Ceiling Exhaust Only Hoods (GASLP2 SERIES)
The GASLP2 Series is a Type I, Sloped Wall Canopy Hood for use over 400°F and 600°F cooking surface temperatures. The Sloped Canopy is the ideal hood choice for low ceiling heights.
Product Description
- ETL Listed: ETL Listed for use over 400°F and 600°F cooking surface temperatures, which provides flexibility in designing kitchen ventilation systems. ETL Listed to US and Canadian safety standards, ETL Sanitation Listed and built in accordance with NFPA 96.
- Capture and Containment: Insulated, double-wall rigid front has aerodynamic design that reduces radiant heat into kitchen, prevents condensation and provides exceptional capture and containment of cooking vapors. The signature “mechanical baffle” on the front of the hood’s capture area is available on 18″ Front Model only. The mechanical baffle provides a built-in wiring chase for optimal positioning of electrical controls and outlets on the front face of the hood without penetrating capture area or requiring external chase way.
- Convenient Design: Factory pre-wired lighting to illuminate the cooking surface is accessible from the bottom of the hood. Fitted with UL Listed, pre-wired, incandescent light fixtures and tempered glass globes to hold up to a standard 100 watt bulb. Pre-punched hanging angles on each end of hood and additional set provided for hoods longer than 12′.
- Construction: Polished stainless steel on the interior and exterior of the front enhance aesthetics. Fully welded and polished front corners. Fabricated from Type 430 stainless steel with option of Type 304 available. Sloped front for low ceiling applications.
- Grease Extraction: All hoods come standard with stainless steel baffle filters and a deep grease trough which allows for easy cleaning. Captrate Combo® and Captrate Solo® filters are optional. Grease drain system with removable 1/2 pint cup for easy cleaning. Standard filter stops eliminate gaps between filters.
- Reduced Lead Times and Shipping Costs: Produced on a high volume assembly line at one of six manufacturing facilities to reduce lead times and shipping costs.
Performance
AVG. COOKING SURFACE TEMP. (°F) | CONFIGURATION | MIN. EXHAUST CFM / FT. |
---|---|---|
400°F | Single Wall Hood 2 Wall Hoods Back-to-Back | 228 456 |
600°F | Single Wall Hood 2 Wall Hoods Back-to-Back | 294 588 |
Recommended Duct Sizing: Exhaust – Based on 1500 FPM
- Controls: Hoods can be equipped with modular utility cabinets and end standoffs. Optional listed light and fan control switches flush mounted and pre-wired through electrical chase way.
Reduced Weight: Rigid single wall end panels reduce weight. - Optional Make-Up Air: Make-up air can be supplied through optional front and/or side plenums (ND-2 Series with PSP or AC-PSP Accessory).
- Optional Self Cleaning Technology: The Self Cleaning Hood option adds a spray bar that extends the full length of the hood immediately behind the filters. The system cleans grease from the plenum and portion of the duct with the daily hot water spray cycle.
- Optional CORE Protection: The CORE Fire Protection System is an automatic, pre-engineered fire suppression system which is ETL listed to UL Standard 300. The CORE Protection System is designed to provide primary coverage for ventilating equipment including hoods, ducts, plenum and filters.
- Optional Heat Recovery Coil: This option is available for hoods with CORE Protection. A listed coil accessory can be added to the hood plenum to recover heat from the exhaust stream. Warm air in the exhaust stream passes over the coil and heats the cold water in the coil, acting as a preheater on the hot water supply line for the restaurant or facility.
Features
Heat and Condensate Vent Hood
The GAHB Series is CaptiveAire’s Premier Type II, Exhaust Only hood to be used over equipment not producing grease laden vapors. Type II hoods are used for condensation or heat removal applications.
Product Description
- Exhaust Flow Rates: Superior exhaust flow rates.
- Construction: Single wall type hood fabricated of Type 304 stainless steel, #3 or #4 polish, on all exposed surfaces when used in condensate applications. Type 430 stainless steel, #3 or #4 polish available when used for heat applications. Pre-punched hanging angles on each end of hood. Additional set provided for hoods longer than 12′.
- Condensate Applications: Integral 4-sided perimeter gutter and one drain standard for high-moisture exhaust.
- Reduced Lead Times and Shipping Costs: Produced on a high volume assembly line at one of six manufacturing facilities to reduce lead times and shipping costs.
Performance
CONFIGURATION | LIGHT LOAD EXHAUST CFM / FT. | HEAVY LOAD EXHAUST CFM / FT. |
---|---|---|
Wall & 1-piece island | 100 | 150 |
Recommended Duct Sizing: Exhaust – Based on 800 FPM
- Optional REM Construction: Two options available when removable condensation baffles are required for heavy condensate applications. Designs available for one baffle or two baffle configuration to collect and drain condensation into gutter.
- Optional Double Wall Construction: Double wall front used when switches are needed on the face of the hood and/or lights are desired. Mechanical baffle provides a built-in wiring chase for optimal positioning of electrical controls and outlets on the front face of the hood.
- Optional Lights: Incandescent, LED and fluorescent lights are available.
- Optional Make-Up Air: Make-up air can be supplied through optional front and/or side plenums (PSP Accessory).
- Optional Enclosure Panels: Constructed of stainless steel. Sized to extend from hood top to ceiling, enclosing pipe and hanging parts.
Features